Heath Zenith SL-5326 Manual de usuario

Busca en linea o descarga Manual de usuario para Los detectores de movimiento Heath Zenith SL-5326. Heath Zenith SL-5326 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
OPERATION
© 2007 HeathCo LLC 595-4884-20
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
TEST
... back on.
AUTO
1 Second OFF
then...
Put the ON-TIME switch in the
1, 5, or 10 minute position.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Move ON-TIME Switch to
1, 5, or 10 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Model SL-5411
Light Control
Sensor
Cover
Plate
Lamp
Holders
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Motion Sensor Light
Control
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Plastic Hanger
Rubber Plug
Gasket
Mounting Strap
Mounting Bolt
2 Wire
Connectors
As an ENERGY STAR
®
Partner, Heath
®
/Ze-
nith has determined that this product meets
the ENERGY STAR
®
guidelines for energy
efficiency. This product is ENERGY STAR
®
compliant when used with 120 Watt bulbs.
This package includes:
6 Screws
(3 sizes included)
Mode: On-Time Works: Day Night
Test
5 Seconds x x
Auto
1, 5, or 10 Minutes x
Manual
To Dawn* x
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - Motion Sensor Light

OPERATION© 2007 HeathCo LLC 595-4884-20* resets to Auto Mode at dawn.MANUAL MODEON-TIME10 5 1 TEST10 5 1 TESTON-TIMETEST... back on.AUTO1 Second OFF

Pagina 2

10595-4884-20INSTALLATIONPour faciliter l’installation, choisir un appareil d’éclairage devant être remplacé et qui est déjà commandé par un interrupt

Pagina 3 - SPECIFICATIONS

11595-4884-20ESSAIS ET RÉGLAGES❒ Mettre en circuit le disjoncteur et l’interrupteur d’éclairage.❒ Placez la commande RANGE à sa position inter

Pagina 4 - TROUBLESHOOTING GUIDE

12595-4884-20GUIDE DE DÉPANNAGESYMPTÔMEL’éclairage ne s’allume pas.L’éclairage s’allume en plein jour.L’éclairage s’allume sans rai-son apparente.CAUS

Pagina 5 - Control de luz del

2595-4884-20INSTALLATIONFor easy installation, select an existing light with a wall switch for replacement.Wire the Light ControL❒ Route the light

Pagina 6 - INSTALACION

3595-4884-20TEST AND ADJUSTMENT❒ Turn on the circuit breaker and light switch.❒ Turn the RANGE control to the mid position and the ON-TIME control t

Pagina 7 - ESPECIFICACIONES

4595-4884-20SYMPTOMLights will not come on.Lights come on in daylight.Lights come on for no apparent reason.POSSIBLE CAUSE1. Light switch is t

Pagina 8 - SERVICIO TÉCNICO

5595-4884-20FUNCIONAMIENTO*Se pone en Automático al amanecer.Para MODO MANUAL:ON-TIME10 5 1 TEST10 5 1 TESTON-TIMEPara PRUEBA:...préndalo.Para AUTOMAT

Pagina 9 - Commande d’éclairage à

6595-4884-20ConeCte eL ControL De LuzINSTALACIONPara una fácil instalación escoja una luz con un interruptor de pared.❒ Conecte los cables d

Pagina 10 - INSTALLATION

7595-4884-20PRUEBA Y AJUSTE❒ Prenda el cortacircuitos y el interruptor de luz.❒ Gire el control RANGE a la posición media y el control ON-TIME a

Pagina 11 - FICHE TECHNIQUE

8595-4884-20GUIA DE INVESTIGACION DE AVERIASSINTOMALa luz no se enci-ende.La luz se prende durante el día.La luz se prende sin ninguna razón

Pagina 12 - SERVICE TECHNIQUE

9595-4884-20FONCTIONNEMENT* Revient au mode automatique au lever du soleil.PRIORITÉ MANUELLEON-TIME10 5 1 TEST10 5 1 TESTON-TIMEESSAIAUTOMATIQUEAmener

Comentarios a estos manuales